Completed work

All sketches at one scale, 1:75.

  1. Water loop volume compensatorHolds loop pressure with a nitrogen cushion and takes up the expansion of water as it heats.Thermal-hydraulic test facility of a research centre, 20242.5 MPa · 200 °C · Ø 1,600
  2. Heat transfer test sectionA vertical channel with a heated tube for measuring heat transfer to water at pressures and temperatures close to a reactor’s.Thermal-hydraulic test facility of a research centre, 20251,200 × 1,200 × 4,600 mm
  3. Blowdown aftercoolerCools blowdown water before the special water treatment filters.VVER-1200 power unit, 20232 MPa · 150 °C · Ø 600
  4. Ion exchange filter for special water treatmentA filter body that takes resin in and out by hydraulic transport.VVER-1200 power unit, 20251 MPa · 70 °C · Ø 1,400
  5. Sodium loop drain tankReceives sodium when the loop is drained and stores it under argon.Sodium loop test facility, 20210.6 MPa · 520 °C · Ø 2,000
  6. Test facility water heaterHeats test section water with steam from the facility boiler.Thermal-hydraulic test facility of a research centre, 20248 MPa · 280 °C · Ø 800
  7. Steam separatorSeparates moisture from steam ahead of the test section.Thermal-hydraulic test facility of a research centre, 20234.5 MPa · 255 °C · Ø 1,000
  8. Controlled leakage tankCollects boric water leakage for return to the circuit.VVER-1200 power unit, 20220.6 MPa · 100 °C · Ø 2,400
  9. Sample coolerCools coolant samples before analysis.VVER-1200 power unit, 202516 MPa · 300 °C · Ø 250
  10. Intermediate circuit heat exchangerRemoves heat from the intermediate cooling circuit to service water.VVER-1200 power unit, 20241.6 MPa · 120 °C · Ø 1,000