What we take on

Products for the customer's design pressure and temperature, from specification to shipment with documents.

Pressure and temperaturePoints are the bureau's completed works, at their design conditions.
04812160100200300400500Design wall temperature, °CDesign pressure, MPaWe take on up to 16 MPa and 530 °CWater loop volume compensator
Inner diameter, mmBars are the range for each product family, points the completed works.
01 0002 0003 000Vessels and tanksShell-and-tube heat exchangersFilters and equipment bodies
The same data as a table
WorkDesign pressure, MPaDesign wall temperature, °CInner diameter, mm
Water loop volume compensator2.52001600
Blowdown aftercooler2150600
Ion exchange filter for special water treatment1701400
Sodium loop drain tank0.65202000
Test facility water heater8280800
Steam separator4.52551000
Controlled leakage tank0.61002400
Sample cooler16300250
Intermediate circuit heat exchanger1.61201000
Materials
Austenitic steels 08Kh18N10T and 12Kh18N10T, plate up to 50 mm; carbon and low-alloy steels by agreement.
Rules
Safety class 3 elements of nuclear plants: NP-089-15, welding to NP-104-18, metal inspection to NP-105-18. Everything else: GOST 34347-2017 and TR CU 032/2013.