Sodium loop drain tank
Sodium loop test facility, 2021
Ø 2,000 × 2,652 mm11.68 m³0.3 MPa, 480 °C12Х18Н10Т
Receives sodium when the loop is drained and stores it under argon.
- Working pressure
- 0.3 MPa
- Working temperature
- 480 °C
- Inner diameter
- 2,000 mm
- Working medium
- sodium
Task
When the loop is drained, sodium must flow into the tank by gravity and stay under argon without freezing.
The bureau’s solution
A vertical tank on a skirt below the loop level, with electric heating of the shell and a drain at the lowest point of the head.
What the bureau did
- design documents
- manufacture
- tests
- installation supervision
Operating conditions
- Design pressure
- 0.6 MPa
- Working pressure
- 0.3 MPa
- Design wall temperature
- 520 °C
- Working temperature
- 480 °C
- Working medium
- sodium
- Rules
- GOST 34347-2017, TR CU 032/2013
Design
- Type
- Vertical vessel
- Inner diameter
- 2,000 mm
- Shell length
- 3,000 mm
- Wall thickness
- 6 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 0.6·2,000 / (2·1·125 − 0.6) = 4.8 mm. With a 1 mm allowance, 6 mm plate was taken. [σ] = 125 MPa for 12Х18Н10Т at 520 °C — GOST 34233.1, table A.3.
- Shell material
- 12Х18Н10Т
- Overall size
- 2,652 × 2,012 × 4,676 mm
- Capacity
- 11.68 m³
- Empty mass
- 1,560 kg
Tests and inspection
- Hydraulic test pressure
- 1.15 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 0.6 · 184 / 125 — GOST 34347, 7.11.3
- Non-destructive testing
- Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds
Product documents
- Passport
- Open for print
- Strength calculation
- in the delivery set
- Operating manual
- in the delivery set
- Metal certificates
- in the delivery set
Lead time
40 weeks from signed specification to shipment
Discuss a similar task
The request starts with a reference to this work; add how your task differs.
Discuss a similar task