Controlled leakage tank
VVER-1200 power unit, 2022
Ø 2,400 × 7,262 mm30.99 m³0.4 MPa, 90 °C08Х18Н10Т
Collects boric water leakage for return to the circuit.
- Working pressure
- 0.4 MPa
- Working temperature
- 90 °C
- Inner diameter
- 2,400 mm
- Working medium
- boric acid solution
Task
Boric water leakage must be collected and returned to the circuit without mixing with other drains.
The bureau’s solution
A 31 m³ horizontal tank with a manhole, a safety valve and a return pump nozzle at the lowest point.
What the bureau did
- design documents
- manufacture
- tests
Operating conditions
- Design pressure
- 0.6 MPa
- Working pressure
- 0.4 MPa
- Design wall temperature
- 100 °C
- Working temperature
- 90 °C
- Working medium
- boric acid solution
- Safety class by NP-001-15
- 3НAssigned by the plant designer and stated in the specification
- Rules
- NP-089-15, NP-104-18, NP-105-18
Design
- Type
- Horizontal vessel
- Inner diameter
- 2,400 mm
- Shell length
- 6,000 mm
- Wall thickness
- 6 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 0.6·2,400 / (2·1·156 − 0.6) = 4.6 mm. With a 1 mm allowance, 6 mm plate was taken. [σ] = 156 MPa for 08Х18Н10Т at 100 °C — GOST 34233.1, table A.3.
- Shell material
- 08Х18Н10Т
- Overall size
- 7,262 × 2,412 × 3,226 mm
- Capacity
- 30.99 m³
- Empty mass
- 3,260 kg
Tests and inspection
- Hydraulic test pressure
- 0.85 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 0.6 · 168 / 156 — GOST 34347, 7.11.3
- Non-destructive testing
- Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds
Product documents
- Passport
- Open for print
- Strength calculation
- in the delivery set
- Operating manual
- in the delivery set
- Metal certificates
- in the delivery set
Lead time
30 weeks from signed specification to shipment
Discuss a similar task
The request starts with a reference to this work; add how your task differs.
Discuss a similar task