Test facility water heater

    Thermal-hydraulic test facility of a research centre, 2024

    Ø 800 × 5,950 mm7.2 MPa, 270 °C12Х18Н10Т

    Heats test section water with steam from the facility boiler.

    Working pressure
    7.2 MPa
    Working temperature
    270 °C
    Inner diameter
    800 mm
    Working medium
    water

    Task

    The test section needs water at 270 °C and 7.2 MPa, and the heat source is steam from the facility boiler.

    The bureau’s solution

    A shell-and-tube heater with water in the tubes and steam in the shell; flanged channels allow the tubes to be cleaned.

    What the bureau did

    1. design documents
    2. manufacture
    3. tests

    Operating conditions

    Design pressure
    8 MPa
    Working pressure
    7.2 MPa
    Design wall temperature
    280 °C
    Working temperature
    270 °C
    Working medium
    water
    Rules
    GOST 34347-2017, TR CU 032/2013

    Design

    Type
    Shell-and-tube heat exchanger
    Inner diameter
    800 mm
    Shell length
    4,500 mm
    Wall thickness
    25 mmBy GOST 34233.2: sₚ = p·D / (2·φ·[σ] − p) = 8·800 / (2·1·150 − 8) = 21.9 mm. With a 1 mm allowance, 25 mm plate was taken. [σ] = 150 MPa for 12Х18Н10Т at 280 °C — GOST 34233.1, table A.3.
    Shell material
    12Х18Н10Т
    Overall size
    5,950 × 1,026 × 1,410 mm
    Empty mass
    7,200 kg

    Tests and inspection

    Hydraulic test pressure
    12.3 MPa1.25 · p · [σ]₂₀ / [σ]ₜ = 1.25 · 8 · 184 / 150 — GOST 34347, 7.11.3
    Non-destructive testing
    Visual and dimensional, liquid penetrant; 100 % radiography of shell butt welds

    Product documents

    Strength calculation
    in the delivery set
    Operating manual
    in the delivery set
    Metal certificates
    in the delivery set

    Lead time

    32 weeks from signed specification to shipment

    Discuss a similar task

    The request starts with a reference to this work; add how your task differs.

    Discuss a similar task